Dell EMC Networking Z9100-ON Z-Series Switch Review


The Dell EMC Networking Switch Z9100-ON Z-Series is a fixed 1U network switch, 10/25/40/50/100GbE, designed to take into account the highest performance. To move this beyond a marketing term, the SCinet with Z9100-ON processor, which is commonly referred to as the "fastest network in the world". The Dell EMC Z9100-ON Z-Series Switch, along with the Dell EMC Networking S4048 S-Series 10GbE Switch, are both part of the latest additions to the StorageReview Enterprise Test Lab's network upgrade. And once again, our review here it examines the switch of the Z-Series Z9100-ON, while at the same time giving the reader a look at why and how we are integrating the switch in our laboratory.
As a wide variety of Dell EMC equipment, the Z9100-ON switch offers customization that allows for greater flexibility. The switch has 128 ports and can be configured to have 32 100 GbE ports, 64 50 GbE ports, 32 40 GbE ports, 128 25 GbE ports or 128 10 GbE ports and two 10 GbE / 1 GbE SFP + ports / 100 Mb. This can help consolidate the rack space and / or help in migration as a data center starts moving at 100 Gbps. The switch also offers organizations a cost-effective method for transitioning to a software-defined data center.

As a multitude of Dell EMC devices, the Z9100-ON Switch offers customization for greater flexibility. The switch has 128 ports and can have 32 100 GbE ports, 64 50 GbE ports, 32 40 GbE ports, 128 25 GbE ports or 128 10 GbE ports and two 10 GbE / 1 GbE SFP + ports. 100 Mb. This can help consolidate rack space and / or support migration when a data center is moving at 100 Gbps. The switch also provides organizations with a cost-effective way to transition to a software-defined data center.

With performance, the Z9100-ON switch takes advantage of the non-blocking switching architecture and offers forwarding capability L2 and L3, along with QoS and a full complement of standards-based IPv4 and IPv6 functions. The switch also incorporates multiple architectural features that are set to optimize the flexibility, efficiency and availability of the data center network. The switch can deliver up to 6.4Tbps of switching I / O bandwidth (full duplex). The multipath support L2 is through virtual trunk link (VLT).

For this power and port level, use cases are still appearing. However, organizations in the Active Fabric deployment process or small Active Fabric deployment can benefit from the Z9100 ON switch as a leaf or spin switch. The switch is also ideal for use with SDN / OpenFlow 1.3.1 with high performance because it is compatible with the standard OpenFlow controllers. The Z9100-ON can be used as a high-speed VXLAN Layer 2 gateway that connects hypervisor-based overlay networks to non-virtualized infrastructure.


Dell EMC Networking Z9100-ON Specifications
AC Base Normal Airflow:
  • 32-port 100G QSFP28, 2 AC PS, 5 fan subsys w/ airflow from I/O PNL to PS

AC Base Reverse Airflow:

  • 32-port 100G QSFP28, 2 AC PS, 5 fan subsys w/ airflow from PS to I/O PNL (TAA versions also available)
Software

  • L3 Dell Networking OS
  • Z9100 series: Dell Networking Software License operating system software license for advanced l3 features, latest version
  • Dell Networking OS
  • Z9100 series: Dell Networking Software License operating system software license, latest version
  • Select third-party operating system offerings
Physical

  • 1 RJ45 console/management port with RS232 signaling
  • 1 10/100/1000bT Ethernet for management
  • 1 USB 2.0 type A storage port
  • 1 micro USB type B port for console/management port access
  • 2 SFP+ 10GbE/1GbE ports for data access
  • Size: 1 RU, 1.72”h x 17.1”w x 18”d
  • Weight: 22 lbs (9.98 kg)
  • ReadyRails rack mounting system, no tools required
Redundancy

  • Two hot swappable power supplies with integrated fans
  • Hot swappable redundant fans
Performance

  • Switching I/O bandwidth: 6.4Tbps
  • Forwarding capacity: Up to 4400 Mpps (Full Duplex)
  • MAC addresses: 136K
  • IPv4 Unicast routes: 136K
  • IPv6 Unicast routes: 68K
  • IPv4 Multicast routes: 68K
  • IPv6 Multicast routes: Not supported
  • Multicast Hosts: 8K
  • ARP entries: 128K
  • Layer 2 VLANs: 4K per port
  • Layer 3 VLANs: Standalone 1K/VLT 4K
  • MST: 64 instances
  • PVST+: 128 instances
  • LAG: 128 groups, 16 members per LAG group
  • LAG load balancing:
  • Based on layer 2, IPv4 or IPv6 headers
  • Latency: Sub 500ns
  • Packet buffer memory: 16MB
  • CPU memory: 8GB
  • QOS data queues: 8
  • QOS control queues: 12
  • QOS: Default 1024 entries scalable to 2.5K
  • ACL Support: 3K
  • Power supply: 100–240 VAC 50/60 Hz
  • Max. power consumption: 605 Watts
  • Typ. power consumption: 195 Watts

Build and Design

The Dell EMC Networking Z9100-ON Z-Series switch is a 1U form factor and, like many Dell EMC switches, it also comes with the Dell ReadyRails system without tools for easy deployment. Along the front of the switch, going from left to right, there is a microUSB-B port, a RJ45 serial console port, a 10/100 / 1000BaseT Ethernet management port, 32 10/25/40 ports / 50/100 QSFP28, two SFP + ports of 1000M / 10G, a battery ID and a USB-A port.

Turning the back of the switch, there are two redundant power supplies on each side with five hot-swappable fan modules in the middle. The switch admits the inversion of the air flow, with the current configuration shown supporting the drawing in cold air from the rear part of the chassis. To change, interchange both power supplies and all five fans with matching airflow directions.
The static rails that Dell offers with the Z9100 switch are very nice. They fit quickly with the receiving rails without tools installed in the frame, and have a very useful hinged front flange that allows the switch to pass through narrow openings and clear wiring. This is much better than switches with fixed tabs that can hit a PDU or trap the wires that come out.

Management

One of the big advantages of the Z9100-ON switch is that it works with so many different network management operating systems. For our review, we use Dell OS 9.10, which has a traditional console as the main administration interface. This is not unusual for many enterprise-level switches, with various essentially handling their basic formations through CLI, even if they have a limited WebGUI. The main purpose for this is that implementation gets faster by simply loading scripts through a Telnet or SSH session.
During our configuration, we started with a local Dell engineer for the initial installation and then worked with Dell ProSupport for a few days to adjust our configuration and work well with our non-standard production environment. However, with most switching configurations, once things work, there's no reason to return to any sort of daily management unless something does not work.

Solutions

Within the larger Dell EMC ecosystem, the Z9100-ON Z-Series switch can be used for several different use cases. In vSAN, for example, the Z9100 can serve as a column switch in the vSAN blade switch architecture. This can lead users to create a simple and scalable network. Users can take advantage of the 40 GbE connection to connect multiple racks and build a large fabric that supports multiple terabyte clusters.

With NSX, again two Z9100-ON Z-Series Switches can be used as spine switches in leaf-thorn topology. The leaf switches will connect to the Z9100-ON with the traffic between the two taking advantage of the same cost multiple route routing (ECMP), using all the available bandwidth. The Z9100-ON can accept up to 32 leaf switches.

The above also applies to a ScaleIO spine design, with the Z9100-ON that allows ample space to climb. If there is no need for redundancy, the customer can choose to use only a Z9100-ON as a leaf switch.

StorageReview Lab Use

At StorageReview Lab, we leverage a set of Dell EMC Networking Z9100 dual for the primary backbone of our data center. This update was carried out last year, where the main driver was to increase server-to-server bandwidth for faster vMotion times, in addition to faster Ethernet movement. As part of this update, we exchanged our two-port 10G network cards on each server for 25G Mellanox NIC dual-port cards. Each of our Dell PowerEdge R730 and R740xd servers has a connection to each switch, with traffic balanced on each for our test purposes.
The migration to 25/50 / 100G networks for StorageReview could not have happened at a better time. With the release of the VMware3 standard from VMware last year, we have been taking advantage of the fastest network speeds for our shipments. With faster network movements working toward the final score, we can post higher infrastructure scores than others that still use 10G. In the real world this translates into smaller vMotion windows and offers more bandwidth to applications that can take advantage of it, using fewer cables.
Another additional benefit of a 100G network is the future protection of our storage fabric. With many new storage platforms that support 100G links to the array, this allows much higher throughput through fewer network links. It also allows individual servers to consume more bandwidth for burst activities.

Conclusion

The Z9100-ON was the first on the market with a 100GbE multi-rate dense switch, an achievement that is more than an edge advantage for the Dell EMC network division. Only occupying 1U of space, the change is about performance and connectivity. The Z9100-ON takes advantage of the non-blocking switching architecture and offers forwarding capability L2 and L3 along with QoS for best performance. The switch delivers up to 6.4Tbps of I / O bandwidth (in full duplex). In terms of connectivity, the Z9100 has 128 ports that can be configured as 32 100GbE ports, 64 50GbE ports, 32 40GbE ports, 128 25GbE ports or 128 10GbE ports and two 10GbE / 1GbE / 100MbE SFP + ports. This large number of ports, together with the configuration capacity, can help data centers consolidate or facilitate them in their migration path at higher network speeds.

The pair Z9100 in our lab is fundamental to the infrastructure. In a comparative assessment, the main objective is to emphasize the memory under review as much as possible. With the new structure of Dell Networking, we can offer the best network available. Nowhere is this more evident than in VMmark, where scores due to data migration (vMotion) are heavily dependent on network quality. Our approach to virtual virtualization testing with VMmark shows what true clusters really do in the real world. We're not targeting the number of inflated heroes like most server shipments. Instead, we illustrate what a typical environment would look like in a highly virtualized enterprise, where the Z9100 switches play a vital role in unlocking the potential of servers and storage.

The Bottom Line
The Z9100-ON switch series offers organizations the ability to consolidate networks, scale to larger clusters and prepare them for future network speeds. The Z9100 have been taken by the workhorses in our environment, offering both high performance and flexibility for a wide range of devices under test.

Monday 19 February 2018

EMC E22-285 Exam Dumps Questions - EMC E22-285 Exam Braindumps Dumps4download.us

Question No : 1

An ESRS deployment on a VxRail system with external vCenter fails with “Invalid target datastore specified”. What is required to resolve this problem?

A. Open a Service Request to involve support
B. Retry deployment through the retry button
C. Manually deploy ESRS
D. Restart vCenter services and retry the deployment

Answer: D

Question No : 2

During a VxRail installation, the deployment fails at 9%. Based on the exhibit, what could be the reason for this failure?

A. Domain name .local is not supported
B. Password field has an extra space
C. vCenter and PSC information is missing
D. Timezone is in an incorrect format

Answer: C


Free EMC E22-285 Sample Question - 2018 EMC E22-285 Exam Dumps Dumps4download.us












Question No : 3
What is the Dell EMC product that is purpose-built for departmental and edge applications, as well as small enterprise and mid-market data centers?

A. Vscale Architecture
B. VxRail
C. VxRack
D. Vblock/VxBlock

Answer: B
Explanation:
VxRail Appliances are purposebuilt for departmental and edge applications as well as small enterprise and mid-market data centers. Like VxRack Systems they do not contain a storage array, but instead run a software-defined storage environment on the appliance.They are built using standard x86 hardware, and tend to focus on ease of use and use case specific features. VxRail Appliances scale from 4 to 64 nodes.

Question No : 4
Which VxRail node type supports only hybrid storage?

A. S Series
B. E Series
C. G Series
D. V Series

Answer: A
Explanation: 
Reference 
https://www.emc.com/en-us/converged-infrastructure/vxrail/index.htm#collapse=



Download EMC E22-285 Exam Real Questions - EMC E22-285 Exam Study Material Dumps4download.us


Question No : 5
A company intends to deploy VxRail with support for GPU cards. Which type of VxRail nodes should be recommended?

A. E Series
B. V Series
C. G Series
D. P Series

Answer: B

Question No : 6
The Market Place on a VxRail Manager is empty on a newly deployed system. Testing shows that the Internet is reachable through proxy in the management network.Which action should be taken to correct this situation?

A. VxRail Manager has no proxy support.
B. Upgrade tolatest version and add proxy configuration manually.
C. Manually add the proxy information in the VxRail Manager configuration
D. Reset the appliance and redeploy with proxy information filled in the deployment process.

Answer: B



Latest EMC E22-285 Exam Question Answer - EMC E22-285 Dumps Exam Dumps4download.us


Question No : 7
A planned VxRail deployment will use an External vCenter Server and syslog server.Which ping connectivity tests should succeed and which should fail before the deployment?

A. Succeed: ESXi hosts and syslogFail: VxRail Manager and vCenter
B. Succeed: VxRail Manager and ESXi hostsFail: vCenter and syslog server
C. Succeed: vCenter and syslog serverFail: VxRail Manager and ESXi hosts
D. Succeed: VxRail Manager and syslogFail: vCenter and ESXi hosts

Answer: A

Question No : 8
You have been asked to install a 7 node VxRail single socket 1 GbE G Series cluster. The company has requested remote KVM support.How many RJ45 cables will be required?

A. 14
B. 21
C. 28
D. 35

Answer: A
Explanation:
Reference:
https://www.emc.com/collateral/technical-documentation/h15104-vxrailappliance-techbook.pdf


Exact EMC E22-285 Exam Question - EMC E22-285 Braindumps PDF Dumps4download.us



Question No : 9

Which network traffic types require the specification of a VLAN ID in the VxRail PreInstallation
Site Checklist?

A. Fault Tolerance, vMotion, vSAN, and user VM Network
B. Management, vMotion, and vSAN only
C. Management, vMotion, vSAN, and user VM Network
D. vMotion, vSAN, and user VM Network only

Answer: B

Question No : 10
Which VxRail Manager tab is used to set up the EMC Online Support Account and ESRS?

A. HEALTH
B. SUPPORT
C. DASHBOARD
D. CONFIG

Answer: B
Explanation:
Reference:
https://learningcontent.emc.com/gatekeepercontent/cninv000000000136183/stor y_content/external_files/VxRail%20Lab%20Guide-Admin%20and%20Management4.0-
v2_ID.pdf



2018 EMC E22-285 Real Exam Questions - EMC E22-285 Braindumps Dumps4download.us


                                                                            

Monday 5 February 2018

Free E22-285 Exam Question Answers - EMC E22-285 Braindumps Dumps4Download.us

Question No : 3

What is the VxRail maximum cluster size if using only 1 GbE links?
A. 8
B. 16
C. 32
D. 64 with an RPQ

Answer: A
Explanation:
Referenc:
https://www.emc.com/collateral/specification-sheet/vxrail-4.0-spec-sheet.pdf

Free E22-285 Exam Question Answers - EMC E22-285 Braindumps Dumps4Download.us

Friday 12 January 2018

2018 Latest EMC E22-285 Dumps Questions - Updated EMC E22-285 Dumps

Fully Updated 2018 Dumps4Download E22-285 Dumps - E22-285 Best Study Guide

Question No : 2

What accurately describes VxRail scale-out rules?

A. Only the first 3 cluster nodes must be identical
B. Mixing hybrid and all-flash nodes is permitted when scaling greater than 32nodes with an RPQ
C. All G series models in a cluster must be identical
D. Only the first 4 cluster nodes must be identical

Answer: C 
Explanation: 
Reference
http://www.snsltd.co.uk/Presentations/Dell_EMC_VxRail_Overview.pptx

Best EMC E22-285 Study Material - Download Updated E22-285 Questions

Question No : 1

An all-flash VxRail cluster has just been deployed. When attempting to enable compression, the option is grayed out. What is the cause of this situation?

A. “Add disks to storage” is set to manual
B. Erasure Coding is not enabled
C. Erasure Coding is not disabled
D. “Add disks to storage” is set to automatic

Answer: D